iCup™ 3-Panel Rapid Drug Test Cup, I-DOA-1237 | Abbott Toxicology, 25/Box
Brand : iCUP™ Urine Test
- SKU:
- I-DOA-1237
Alere Toxicology iCup 3-Panel Instant Drug Test Cup
The iCup Drug Screen Cup is the simplest, self-contained one step drug test. Results are visible within minutes. A positive result is indicated with one line and a negative result with two. An additional bonus with the iCup is that you may photocopy the results allowing you to maintain a visual record of the test.
The iCup offers a completely closed system for total urine specimen integrity and easy collection. The clear construction gives optimum observation of urine specimen. The iCup drug screen kit is a single unit with no dipping or pouring. Test results develop quickly in the sealed unit. The system remains closed until disposal of the device.The iCup drug screen is zero exposure, leak-proof and tamper-proof. The iCup cup can be ordered with combinations from 3 to 13 panels.
Features & Benefits
- Sold by the Box of 25 Test Kits
- Photocopy Template and Two-part Result Available - Mark Box Above
- Security Seal
- FDA 510(k) Cleared
- Temperature Strip
- Room temperature storage
- SAMHSA Lab GC/MS Confirmation Optional - Call for Information
- Built-in Validity Test
- Immediate Results
- Detects from 3 to 13 Drugs
- Simple Procedure
- Fast Results
- Adheres to SAMHSA Cutoff Levels
- Cut-offs Levels of Drug Testing Set According SAMHSA
- Shelf-life 24 Months from Date of Manufacturer
- 99% Accurate Test Results in 5 Minutes
What's Included?
i-Cup comes with kit, cup, security seal, and drug screen result form. The iCup drug screen result form shows a diagram of the iCup and gives an example of positive results, negative results & invalid results. The form provides the names of each drug and their abbreviations making your job easier! Not to mention a product insert, a step by step instruction display for your staff. The iCup drug screen includes a temperature strip located on the back of the cup. This helps to insure specimen integrity. The I-Cup drug screen also includes a quality control device built into the test itself, and a red line in the control region (C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique.
3 Panel i-Cups (Select Item Number Link Below to Jump to Desired Panel) | ||
Item Number | Drug Panels Tested | Adulterants Tested |
I-DOA-1237 | COC300, mAMP1000, THC50 | None |
I-DOA-3137 | COC300, OPI2000, THC50 | None |
* Detection times are not guaranteed. This assay provides only a preliminary test result. A more specific alternative chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary results are positive. The above chart gives approximate detection periods for each substance by test type. The ranges depend on amount and frequency of use, metabolic rate, body mass, age, overall health, drug tolerance, and urine pH. | ||
iCup Cut-off Levels and Detection Times | ||
---|---|---|
Drug Panel | Cut-Off Level | Detection Time |
Amphetamine (AMP) | 1,000 ng/ml | 2 – 4 Days |
Amphetamine (AMP300) | 300ng/ml | 2 – 4 Days |
Barbiturates (BAR) | 300 ng/ml | 4 – 7 Days |
Benzodiazepines (BZO) | 300 ng/ml | 3 – 7 Days |
Buprenorphine (BUP) | 10 ng/ml | 1 – 3 Days |
Cocaine (COC) | 300 ng/ml | 2 – 4 Days |
Cocaine (COC150) | 150 ng/ml | 2 – 4 Days |
Ecstasy (MDMA) | 500 ng/ml | 1 – 3 Days |
Methadone (MTD) | 300ng/ml | 3 – 5 Days |
Methamphetamine (MET) | 1,000 ng/ml | 3 – 5 Days |
Methamphetamine (MET500) | 500 ng/ml | 3 – 5 Days |
Opiates (MOR) | 300 ng/ml | 2 – 4 Days |
Opiates (OPI) | 2,000 ng/ml | 2 – 4 Days |
Phencyclidine (PCP) | 25 ng/ml | 7 – 14 Days |
Marijuana (THC) | 50 ng/ml | 15 – 30 Days |
Tri-Cyclic Antidepressants (TCA) | 1,000 ng/ml | 7 – 10 Days |
Propoxyphene (PPX) | 300 ng/ml | 1 – 2 Days |
Oxycodone (OXY) | 100 ng/ml | 2 – 4 Days |